Difference between revisions of "Fuel chamber"
Jump to navigation
Jump to search
(updated mass amounts) |
|||
| (14 intermediate revisions by 5 users not shown) | |||
| Line 3: | Line 3: | ||
|ua=Паливна камера | |ua=Паливна камера | ||
|jp=燃料チャンバー | |jp=燃料チャンバー | ||
}}{{SB Infobox Begin | }}{{SB Infobox Begin | ||
|{{SB Infobox Header | |{{SB Infobox Header | ||
| Line 23: | Line 22: | ||
}}<section begin=summary/>Fuel chambers are an integral part of [[Generator_(Assembly)|generators]], as they convert raw fuel from [[Fuel rod|fuel rods]] and deliver processed fuel to [[Generator_unit|generator units]].<section end=summary/> | }}<section begin=summary/>Fuel chambers are an integral part of [[Generator_(Assembly)|generators]], as they convert raw fuel from [[Fuel rod|fuel rods]] and deliver processed fuel to [[Generator_unit|generator units]]. Their conversion efficiency can be significantly increased with [[Enhancer|enhancers]].<section end=summary/> | ||
== Basic Usage == | == Basic Usage == | ||
* '''NOTE!''' tier 1 generator parts are not compatible with Tier 2 or 3. | * '''NOTE!''' tier 1 generator parts are not compatible with Tier 2 or 3. This means that a Tier 1 Fuel chamber cannot feed Tier 2 or Tier 3 generators, and Tier 1 generators cannot accept [[exorium]] (tier 2) fuel. | ||
** Tier 2 and tier 3 parts are compatible. | ** Tier 2 and tier 3 parts are compatible, for example you can use Tier 2 fuel chambers with Tier 3 generators and have no compatibility issues. | ||
| Line 39: | Line 38: | ||
* Fuel chambers produce heat proportional to their unit rate. | * Fuel chambers produce heat proportional to their unit rate. | ||
** See [[Generator_(Assembly)#Heat_and_cooling|heat and cooling]] for more info. | |||
** See [[heat | |||
* T1 fuel chambers require a [[nhurgite]] [[fuel rod]], T2 and T3 fuel chambers require an [[exorium]] [[fuel rod]]. | * T1 fuel chambers require a [[nhurgite]] [[fuel rod]], T2 and T3 fuel chambers require an [[exorium]] [[fuel rod]]. | ||
* One fuel rod can support three generator units, or 3000 (3750 for T3) units of electricity per second. | * One fuel rod can support three generator units, or 3000 (3750 for T3) units of electricity per second, without enhancement. | ||
* | * If an enhancement effect is used on the fuel chamber, the efficiency rate of processing '''Processed Fuel''' from '''Raw Fuel''' increases. | ||
== Types == | == Types == | ||
| Line 57: | Line 55: | ||
|{{SB Infobox Device General Information | |{{SB Infobox Device General Information | ||
|mass= | |mass=9374.88 | ||
|volume=765.83 | |volume=765.83 | ||
|size=192×96×96 cm | |size=192×96×96 cm | ||
| Line 65: | Line 63: | ||
|{{SB Infobox Device IO | |{{SB Infobox Device IO | ||
|heatOut= | |heatOut=100 per second | ||
|fuelIn=90 per second ''(raw)'' | |fuelIn=90 per second ''(raw)'' | ||
|fuelOut=75 per second ''(refined)'' | |fuelOut=75 per second ''(refined)'' | ||
|modInterfaces=9 | |modInterfaces=9 | ||
|enhancement=<ul><li>66% efficiency (1x)</li><li>100% efficiency (2x)</li><li>116% efficiency (3x)</li></ul> | |||
}} | }} | ||
| Line 86: | Line 84: | ||
|{{SB Infobox Device General Information | |{{SB Infobox Device General Information | ||
|mass= | |mass=9722.29 | ||
|volume=765.83 | |volume=765.83 | ||
|size=192×96×96 cm | |size=192×96×96 cm | ||
| Line 94: | Line 92: | ||
|{{SB Infobox Device IO | |{{SB Infobox Device IO | ||
|heatOut= | |heatOut=90 per second | ||
|fuelIn=60 per second ''(raw)'' | |fuelIn=60 per second ''(raw)'' | ||
|fuelOut=75 per second ''(processed)'' | |fuelOut=75 per second ''(processed)'' | ||
|modInterfaces=9 | |modInterfaces=9 | ||
|enhancement=<ul><li>100% efficiency (1x)</li><li>150% efficiency (2x)</li><li>175% efficiency (3x)</li></ul> | |||
}} | }} | ||
| Line 116: | Line 114: | ||
|{{SB Infobox Device General Information | |{{SB Infobox Device General Information | ||
|mass= | |mass=9,851.01 | ||
|volume=765.83 | |volume=765.83 | ||
|size=192×96×96 cm | |size=192×96×96 cm | ||
| Line 127: | Line 125: | ||
|fuelIn=60 per second ''(raw)'' | |fuelIn=60 per second ''(raw)'' | ||
|fuelOut=75 per second ''(processed)'' | |fuelOut=75 per second ''(processed)'' | ||
|modInterfaces=9 | |modInterfaces=9 | ||
|enhancement=<ul><li>100% efficiency (1x)</li><li>150% efficiency (2x)</li><li>175% efficiency (3x)</li></ul> | |||
}} | }} | ||
| Line 141: | Line 139: | ||
}} | }} | ||
}} | }} | ||
== Device fields == | == Device fields == | ||
| Line 175: | Line 146: | ||
! Description | ! Description | ||
! Range | ! Range | ||
|- | |- | ||
! '''FuelChamberFuel''' | ! '''FuelChamberFuel''' | ||
| | |The amount of fuel currently available in this chamber's fuel rod | ||
| 0 - 300000 | | 0 - 300000 | ||
|- | |- | ||
| Line 188: | Line 155: | ||
| 0 - 300000 | | 0 - 300000 | ||
|- | |- | ||
! ''' | ! '''FuelChamberConversionRate''' | ||
| | |Fuel Chamber conversion rate, 0-135 in tier 1 and 0-60 in tier 2-3 chambers | ||
| 0 - | | 0-135 or 0-60 | ||
|- | |- | ||
! '''FuelChamberUnitRateLimit''' | ! '''FuelChamberUnitRateLimit''' | ||
| Line 201: | Line 164: | ||
|- | |- | ||
! '''FuelChamberUnitRate''' | ! '''FuelChamberUnitRate''' | ||
|Current conversion rate for this fuel chamber | |Current conversion rate for this fuel chamber. Conversion is being performed at 1 conversion * this percentage per second | ||
| 0 - 100 | | 0 - 100 | ||
|- | |- | ||
Revision as of 12:33, 23 September 2021
Fuel chambers are an integral part of generators, as they convert raw fuel from fuel rods and deliver processed fuel to generator units. Their conversion efficiency can be significantly increased with enhancers.
Basic Usage
- NOTE! tier 1 generator parts are not compatible with Tier 2 or 3. This means that a Tier 1 Fuel chamber cannot feed Tier 2 or Tier 3 generators, and Tier 1 generators cannot accept exorium (tier 2) fuel.
- Tier 2 and tier 3 parts are compatible, for example you can use Tier 2 fuel chambers with Tier 3 generators and have no compatibility issues.
- Receives Raw Fuel from the fuel rod and converts it to Processed Fuel.
- This process also generates Heat.
- Distributes Processed Fuel to generator units.
- There are nine connectors, two on each long side and one on the "back" side of the chamber.
- Other modules can be attached to the connectors.
- Fuel chambers produce heat proportional to their unit rate.
- See heat and cooling for more info.
- T1 fuel chambers require a nhurgite fuel rod, T2 and T3 fuel chambers require an exorium fuel rod.
- One fuel rod can support three generator units, or 3000 (3750 for T3) units of electricity per second, without enhancement.
- If an enhancement effect is used on the fuel chamber, the efficiency rate of processing Processed Fuel from Raw Fuel increases.
Types
Tier 1 fuel chamber
Size 192×96×96 cm
Mass 9374.88 kg
Volume 765.83 kv
Corrosion resistance 300
Primary material Bastium
Input / Output
Fuel input 90 per second (raw)
Fuel output 75 per second (refined)
Modular interfaces 9
Enhancement effect
- 66% efficiency (1x)
- 100% efficiency (2x)
- 116% efficiency (3x)
Composition
Tier 2 fuel chamber
Size 192×96×96 cm
Mass 9722.29 kg
Volume 765.83 kv
Corrosion resistance 380
Primary material Aegisium
Input / Output
Fuel input 60 per second (raw)
Fuel output 75 per second (processed)
Modular interfaces 9
Enhancement effect
- 100% efficiency (1x)
- 150% efficiency (2x)
- 175% efficiency (3x)
Composition
Tier 3 fuel chamber
Size 192×96×96 cm
Mass 9,851.01 kg
Volume 765.83 kv
Corrosion resistance 485
Primary material Ymrium
Input / Output
Fuel input 60 per second (raw)
Fuel output 75 per second (processed)
Modular interfaces 9
Enhancement effect
- 100% efficiency (1x)
- 150% efficiency (2x)
- 175% efficiency (3x)
Composition
Device fields
| YOLOL field | Description | Range |
|---|---|---|
| FuelChamberFuel | The amount of fuel currently available in this chamber's fuel rod | 0 - 300000 |
| FuelChamberMaxFuel | Maximum amount of fuel that can be stored in this chamber's rod, zero if no rod | 0 - 300000 |
| FuelChamberConversionRate | Fuel Chamber conversion rate, 0-135 in tier 1 and 0-60 in tier 2-3 chambers | 0-135 or 0-60 |
| FuelChamberUnitRateLimit | Upper limit for conversion rate for this fuel chamber, as a percentage. | 0 - 100 |
| FuelChamberUnitRate | Current conversion rate for this fuel chamber. Conversion is being performed at 1 conversion * this percentage per second | 0 - 100 |
To learn more about how to use fields, consult these wiki pages: