Sb forum speech.png DiscordLink.png FacebookLink.png RedditLink.png SteamLink.png TwitterLink.png YoutubeLink.png

Difference between revisions of "Generator unit"

From Starbase wiki
Jump to navigation Jump to search
(Minor edit to reflect some of the numerical changes in update 18-6-2021 alpha 485.2001 for tiered generators. Formatting may be necessary.)
(→‎Basic Usage: Corrections and updates)
Line 76: Line 76:


== Basic Usage ==
== Basic Usage ==
* '''NOTE!''' tier 1 generator parts are not compatable with Tier 2 or 3.
** Tier 2 and tier 3 parts are compatable.


* Receives '''Processed Fuel''' from the fuel chamber and converts it to '''Power'''.
* Receives '''Processed Fuel''' from the fuel chamber and converts it to '''Power'''.
** This process also generates '''Heat'''.
** This process also generates '''Heat'''.
** '''NOTE!''' The generators will constantly consume '''Processed fuel''', wasting excess '''Power''' unless their ''ConversionRateLimit'' is modified via [[YOLOL|YOLOL]]
** '''NOTE!''' The generators will constantly consume '''Processed fuel''', wasting excess '''Power''' unless their ''ConversionRateLimit'' is modified via [[YOLOL|YOLOL]].
* There are six connectors, one on each side.
* There are six connectors, one on each side.
* Other modules can be attached to the connectors.
* Other modules can be attached to the connectors.
** For every adjacent generator unit, extra heat will be generated.
 
<!-- ** '''Tip:''' If generator units are stacked close together, extra benefit can be gained from the enhancers. However, this generates more heat, which must be cooled down.
 
* If an enhancement effect is used on the generator unit, the efficiency of processing '''Power''' from '''Processed Fuel''' increases. -->
* Generators produce heat proportinal to their unit rate.
* Produces 1000 units of electricity per second, if enough fuel is available.
* For every adjacent generator unit, extra heat will be generated.
* One fuel rod can support three tier one (T1) or tier two (T2) generator units, or 3000 units of electricity per second. (Verification requested from CA tester for tier 2)
** Adjacency heat, for all tiers, and from 1 unit to 6, is as follows: 25, 55, 95, 145, 205, 280.
* Five fuel rods can (theoretically) support twelve tier three (T3) generator units at 15,000 units of electricity, while it would take 15 tier one (T1) or tier 2 (T2) generators to sustain such generation.  
** See [[Generator_(Assembly)#Heat_and_cooling|heat and cooling]] for more info.
** With an enhanced fuel chamber, a fuel rod can support more generator units.
 
 
* T1 and T2 units produce 1000 units of electricity per second, if enough fuel is available, T3 units can produce 1250 units of electricity per second.
* One fuel rod can support three generator units, or 3000 units of electricity per second, without enhancement.
** With an enhanced fuel chamber, a fuel rod can support more generator units. See [[enhancer]]s for more info.


== Device fields ==
== Device fields ==

Revision as of 18:52, 23 June 2021

Українська 日本語 简体中文
Starbase devices generator unit.png
Generator unit
Type Power device
Function Converts fuel to power
Availability Luxury Items
Size 96×96×96 cm
Mass 44,920.63 kg
Volume 4,645.36 kv
Corrosion resistance 230

Input / Output

Electric output 1,000 e/s (T1/T2) 1,250 e/s (T3)

Heat generation 100 per second (T1), 90 per second (T2), 80 per second (T3)

Fuel input 25 per second

Modular interfaces 6

Enhancement effect +500/+750/+875 (T1 calculations only)
Composition

Generators are one of the most important parts of a spaceship, as they convert fuel into electrical energy in an efficient process. They are extremely modular, and can be configured into complexes of many different shapes and sizes - however, for each adjacent generator, the heat output is also increased.

Basic Usage

  • NOTE! tier 1 generator parts are not compatable with Tier 2 or 3.
    • Tier 2 and tier 3 parts are compatable.


  • Receives Processed Fuel from the fuel chamber and converts it to Power.
    • This process also generates Heat.
    • NOTE! The generators will constantly consume Processed fuel, wasting excess Power unless their ConversionRateLimit is modified via YOLOL.
  • There are six connectors, one on each side.
  • Other modules can be attached to the connectors.


  • Generators produce heat proportinal to their unit rate.
  • For every adjacent generator unit, extra heat will be generated.
    • Adjacency heat, for all tiers, and from 1 unit to 6, is as follows: 25, 55, 95, 145, 205, 280.
    • See heat and cooling for more info.


  • T1 and T2 units produce 1000 units of electricity per second, if enough fuel is available, T3 units can produce 1250 units of electricity per second.
  • One fuel rod can support three generator units, or 3000 units of electricity per second, without enhancement.
    • With an enhanced fuel chamber, a fuel rod can support more generator units. See enhancers for more info.

Device fields

YOLOL field Description Range
GeneratorUnitRateLimit Upper limit for conversion rate for this generator block 0 - 100
GeneratorUnitRate Current conversion rate for this generator block. Conversion is being performed at 1 conversion * this percentage per second. 0 - 100

To learn more about how to use fields, consult these wiki pages:

Related Articles

Generator unit
Cookies help us deliver our services. By using our services, you agree to our use of cookies.