Sb forum speech.png DiscordLink.png FacebookLink.png RedditLink.png SteamLink.png TwitterLink.png YoutubeLink.png

Difference between revisions of "Enhancer"

From Starbase wiki
Jump to navigation Jump to search
(Enhancement for T1 fuel chamber was incorrect. It is actually 66%/100%/116% instead of 100%/150%/175%. Was thoroughly tested in SSC.)
(3 intermediate revisions by 2 users not shown)
Line 18: Line 18:
}}
}}


}}<section begin=summary/>Enhancers are devices that can attach to a [[Generator_(Assembly)|generator]] and provide boosts to the generation of power. Currently, only [[Generator unit|generator units]] are affected by enhancers.<section end=summary/>
}}<section begin=summary/>Enhancers are devices that can attach to a [[Generator_(Assembly)|generator]] and provide boosts to some device characteristics. Only the devices that are within a specific range of the enhancer's modular interface side are affected, and this range varies between tiers of enhancers.<section end=summary/>


== Types ==
== Types ==
Line 42: Line 42:


  |{{SB Infobox Device Construction
  |{{SB Infobox Device Construction
|charodium=25%
|aegisium=25%
|exorium=25%
|kutonium=15%
|bastium=20%
|arkanium=15%
|vokarium=15%
|corazium=10%
|exorium=20%
|karnite=15%
|karnite=15%
  }}
  }}
}}
}}
Line 70: Line 70:


  |{{SB Infobox Device Construction
  |{{SB Infobox Device Construction
|exorium=22%
|ymrium=15%
|aegisium=20%
|kutonium=15%
|arkanium=18%
|arkanium=15%
|kutonium=18%
|xhalium=10%
|corazium=12%
|karnite=10%
|karnite=10%
|lukium=20%
  }}
  }}
}}
}}
Line 99: Line 99:


  |{{SB Infobox Device Construction
  |{{SB Infobox Device Construction
|ymrium=12%
|ymrium=15%
|kutonium=14%
|kutonium=10%
|arkanium=16%
|arkanium=10%
|exorium=16%
|xhalium=15%
|exorium=10%
|karnite=10%
|karnite=10%
|lukium=18%
|lukium=10%
|ukonium=14%
|ilmatrium=20%
  }}
  }}
}}
}}
}}
}}


== Basic Information ==
== Basic Usage ==


Enhancers are used to quickly boost the rate of production of electricity in a generator unit by increasing the efficiency with which they utilize fuel, and can be easily turned on and off with [[YOLOL]]. However, while a generator unit with an attached and activated enhancer unit will produce significantly more electricity, it will also suffer an exponential increase in [[Heat mechanics|heat output]]. While an enhancer can be used to maximize power output (for as long as the cooling performance can keep up), it can also be used to boost efficiency at lower generation states, allowing the production of power at a comparatively lower fuel cost -- though, this will still generate extra heat. Enhancers affect the generation of heat by adding to the quantity of heat tokens held by the device to which they are attached.
* Casts a ray that goes through modules. If the ray hits a module, that module gets the benefit of the enhancement.
** Enhancers increase the efficiency of [[Fuel_chamber|fuel chambers]] and [[Cooling_rack|cooling racks]].
* There are three tiers on the enhancement modules.
** Tier 1 casts a ray that can reach 96 cm (only the module it is attached to).
** Tier 2 that casts a ray that can reach 192 cm (possibly two modules).
** Tier 3 that casts a ray that can reach 288 cm (possibly three modules).
* If several rays are hitting the same module, there will be extra benefit, but with diminishing returns.
** There is no benefit past 3 enhancers.


It should be noted that, though enhancers increase the heat potential of a generator system, enhancers themselves are unaffected by heat.
== Basic information ==


{|class="wikitable mw-collapsible" align="center" style="text-align:center;"
* Only fuel chambers and cooling racks gain an efficiency increase from enhancers.
! colspan=3 | Enhancer Effects
* Fuel chambers will convert the same amount of 'raw fuel' into more 'processed fuel', either allowing for more generator units to be run from one fuel chamber, or for the [[fuel rod]] to last longer.
|-
* Coolant racks will use less coolant to cool the same ammount of heat production.
!Enhancer Tier
!Heat Tokens
!Electricity Production Tokens
|-
|Tier 1
| +3
| +1
|-
|Tier 2
| +4
| +2
|-
|Tier 3
| +5
| +3
|}


 
Enhancer benefit:
The number of electricity production tokens a generator unit has directly affects the boost applied to its output, as shown below:
* One enhancer provides a 40% reduction for T1 and 50% reduction for T2/T3 in fuel/coolant usage. T1 fuel chamber can provide 5 generator units, while T2/T3 fuel chamber can provide 6 generator units with 'processed fuel'.
 
* Two enhancers provide a 50% reduction for T1 and 60% reduction for T2/T3 in fuel/coolant usage. T1 fuel chamber can provide 6 generator units, while T2/T3 fuel chamber can provide 7.5 generator units with 'processed fuel'.
{|class="wikitable mw-collapsible" align="center" style="text-align:center;"
* Three enhancers provide a 53.8% reduction for T1 and 63.6% reduction for T2/T3 in fuel/coolant usage. T1 fuel chamber can provide 6.5 generator units, while T2/T3 fuel chamber can provide 8.25 generator units with 'processed fuel'.
! colspan=3 | Electricity Production Tokens
* Further enhancer rays hitting a device do not provide any more benefit.
|-
<br>
!Electricity Production Tokens
A single fuel chamber, enhanced three times, using three tier 1 enhancers.<br>
!Electrical Output
[[File:GeneratorTier1_3xEnchanced.png|400px]]<br>
|-
Three fuel chambers all enhanced once, using a single Tier 3 enhancer.<br>
| 1
[[File:GeneratorTier3_1xEnchanced.png|400px]]<br>
| +500
|-
| 2
| +750
|-
| 3
| +1,000
|}


== Related Articles ==
== Related Articles ==

Revision as of 09:35, 26 August 2021

Українська 日本語 简体中文
Starbase generator enhancers.png
Tier 1, tier 2, and tier 3 enhancers
Enhancer
Type Utility device
Function Overclocks device performance

Enhancers are devices that can attach to a generator and provide boosts to some device characteristics. Only the devices that are within a specific range of the enhancer's modular interface side are affected, and this range varies between tiers of enhancers.

Types

Enhancer tier 1.png
Tier 1 enhancer

Size 96×96×48 cm
Mass 781.7 kg
Volume 80.84 kv
Corrosion resistance 615
Primary material Aegisium
Input / Output

Modular interfaces 1

Composition

Enhancer tier 2.png
Tier 2 enhancer

Size 96×96×48 cm
Mass 1,135.7 kg
Volume 129.35 kv
Corrosion resistance 380
Primary material Ymrium
Input / Output

Modular interfaces 1

Composition

Lukium 20%

Ymrium 15%
Enhancer tier 3.png
Tier 3 enhancer

Size 96×96×48 cm
Mass 1,709.8 kg
Volume 194.74 kv
Corrosion resistance 445
Primary material Ymrium
Input / Output

Modular interfaces 1

Composition

Lukium 10%

Ymrium 15%

Basic Usage

  • Casts a ray that goes through modules. If the ray hits a module, that module gets the benefit of the enhancement.
  • There are three tiers on the enhancement modules.
    • Tier 1 casts a ray that can reach 96 cm (only the module it is attached to).
    • Tier 2 that casts a ray that can reach 192 cm (possibly two modules).
    • Tier 3 that casts a ray that can reach 288 cm (possibly three modules).
  • If several rays are hitting the same module, there will be extra benefit, but with diminishing returns.
    • There is no benefit past 3 enhancers.

Basic information

  • Only fuel chambers and cooling racks gain an efficiency increase from enhancers.
  • Fuel chambers will convert the same amount of 'raw fuel' into more 'processed fuel', either allowing for more generator units to be run from one fuel chamber, or for the fuel rod to last longer.
  • Coolant racks will use less coolant to cool the same ammount of heat production.

Enhancer benefit:

  • One enhancer provides a 40% reduction for T1 and 50% reduction for T2/T3 in fuel/coolant usage. T1 fuel chamber can provide 5 generator units, while T2/T3 fuel chamber can provide 6 generator units with 'processed fuel'.
  • Two enhancers provide a 50% reduction for T1 and 60% reduction for T2/T3 in fuel/coolant usage. T1 fuel chamber can provide 6 generator units, while T2/T3 fuel chamber can provide 7.5 generator units with 'processed fuel'.
  • Three enhancers provide a 53.8% reduction for T1 and 63.6% reduction for T2/T3 in fuel/coolant usage. T1 fuel chamber can provide 6.5 generator units, while T2/T3 fuel chamber can provide 8.25 generator units with 'processed fuel'.
  • Further enhancer rays hitting a device do not provide any more benefit.


A single fuel chamber, enhanced three times, using three tier 1 enhancers.
GeneratorTier1 3xEnchanced.png
Three fuel chambers all enhanced once, using a single Tier 3 enhancer.
GeneratorTier3 1xEnchanced.png

Related Articles

Cookies help us deliver our services. By using our services, you agree to our use of cookies.