Sb forum speech.png DiscordLink.png FacebookLink.png RedditLink.png SteamLink.png TwitterLink.png YoutubeLink.png

Difference between revisions of "Cooling rack"

From Starbase wiki
Jump to navigation Jump to search
m (Fixed hyperlink to cooling cells, previously referred to as coolant cells.)
Line 73: Line 73:
  |xhalium=
  |xhalium=
}}
}}
}}<section begin=summary/>The cooling rack plays an integral part in a [[Generator_(Assembly)|generator]], as it is one of the only devices that can provide the generator with the cooling capacity that they require to run. Unlike [[Radiator|radiators]], however, cooling racks need to be periodically replenished with refreshed [[Small_cooling_cell|small cooling cell]].<section end=summary/>
}}<section begin=summary/>The cooling rack plays an integral part in a [[Generator_(Assembly)|generator]], as it is one of the only devices that can provide the generator with the cooling capacity that they require to run. Unlike [[Radiator|radiators]], however, cooling racks need to be periodically replenished with refreshed [[Small_cooling_cell|small cooling cells]].<section end=summary/>


== Basic Usage ==
== Basic Usage ==

Revision as of 18:51, 21 June 2021

Українська 日本語 简体中文
Starbase generator coolingboard.png
Cooling rack
Type Power device
Function Provides coolant to generators
Availability Luxury Items
Size 96×96×48 cm
Mass 731.23 kg
Volume 73.49 kv
Corrosion resistance 440

Input / Output

Coolant output 6 per second
Coolant capacity 15,000

Heat dissipation 150 per second

Modular interfaces 1

Composition

The cooling rack plays an integral part in a generator, as it is one of the only devices that can provide the generator with the cooling capacity that they require to run. Unlike radiators, however, cooling racks need to be periodically replenished with refreshed small cooling cells.

Basic Usage

  • The cooling board can hold up to three cooling cells.
  • Receives Coolant from the cooling cells and processes it to reduce Heat.
  • The cooling board can be placed anywhere on a generator, and will provide coolant to each generator of the complex it is directly connected to. Generator complexes connected via pipe will not share coolant.
  • Only the calculated amount of Heat that the system produces is relevant. The cooling power of the cooling board must match the Heat amount produced, or preferably exceed it.
  • There is only one connector on the cooling board.

Device fields

YOLOL field Description Range
CoolerUnitRateLimit Upper limit for conversion rate for this cooler 0 - 100
CoolerUnitRate Current conversion rate for this cooler. Conversion is being performed at 1 conversion * this percentage per second. 0 - 100

To learn more about how to use fields, consult these wiki pages:

Related Articles

Cookies help us deliver our services. By using our services, you agree to our use of cookies.