Difference between revisions of "Socket board"
Jump to navigation
Jump to search
m (cleaned up text about boards per gen units) |
(removed device fields and fixed values that have changed) |
||
(One intermediate revision by one other user not shown) | |||
Line 14: | Line 14: | ||
|{{SB Infobox Device General Information | |{{SB Infobox Device General Information | ||
|type=Power device | |type=Power device | ||
|function= | |function=Allows [[Generator_(Assembly)|generators]] to export power to the network | ||
|size=96×96×48 cm | |size=96×96×48 cm | ||
Line 27: | Line 27: | ||
|{{SB Infobox Device IO | |{{SB Infobox Device IO | ||
|electricIn= | |electricIn=100,000 | ||
|electricOut= | |electricOut=100,000 | ||
|energyCapacity= | |energyCapacity= | ||
|coolantIn= | |coolantIn= | ||
Line 76: | Line 76: | ||
}}<section begin=summary/>The socket board provides an access panel to connect [[Generator_(Assembly)|generators]] to the electricity and data network (cables). | }}<section begin=summary/>The socket board provides an access panel to connect [[Generator_(Assembly)|generators]] to the electricity and data network (cables). | ||
Note that one socket board per | Note that one socket board per 100 tier 1/2 [[generator unit]]s (or 80 tier 3 generator units) is required, if cables are connected via a cube heat sink a socket board is still required to export power.<section end=summary/> | ||
== Basic Usage == | == Basic Usage == | ||
Line 83: | Line 83: | ||
* Connects cables. | * Connects cables. | ||
* Distributes '''Power''' to a [[Data networks|data network]]. | * Distributes '''Power''' to a [[Data networks|data network]]. | ||
* Can distribute a maximum of | * Can distribute a maximum of 100,000 '''Electricity''' per second. | ||
* Doesn't get any benefits from enhancers. | * Doesn't get any benefits from enhancers. | ||
== Related Articles == | == Related Articles == |
Latest revision as of 21:49, 5 May 2022
Socket board
Type Power device
Function Allows generators to export power to the network
Size 96×96×48 cm
Mass 750.93 kg
Volume 75.47 kv
Corrosion resistance 390
Primary material Bastium
Input / Output
Electric input 100,000
Electric output 100,000
Sockets 4
Modular interfaces 1
Composition
The socket board provides an access panel to connect generators to the electricity and data network (cables).
Note that one socket board per 100 tier 1/2 generator units (or 80 tier 3 generator units) is required, if cables are connected via a cube heat sink a socket board is still required to export power.
Basic Usage
- Transforms Local Power into Power.
- Connects cables.
- Distributes Power to a data network.
- Can distribute a maximum of 100,000 Electricity per second.
- Doesn't get any benefits from enhancers.