Difference between revisions of "Cooling rack"
Jump to navigation
Jump to search
m |
m (Fixed hyperlink to cooling cells, previously referred to as coolant cells.) |
||
| (16 intermediate revisions by 4 users not shown) | |||
| Line 14: | Line 14: | ||
|{{SB Infobox Device General Information | |{{SB Infobox Device General Information | ||
|type=Power device | |type=Power device | ||
|function=Provides [[ | |function=Provides [[Coolant|coolant]] to [[Generator_(Assembly)|generators]] | ||
|availability=[[Luxury Items]] | |||
|size=96×96×48 cm | |size=96×96×48 cm | ||
|mass=731.23 | |mass=731.23 | ||
| Line 23: | Line 23: | ||
|suppressUnitsKv | |suppressUnitsKv | ||
|subComponents= | |subComponents= | ||
}} | }} | ||
| Line 31: | Line 30: | ||
|energyCapacity= | |energyCapacity= | ||
|coolantIn= | |coolantIn= | ||
|coolantOut= | |coolantOut=6 per second | ||
|coolantCapacity= | |coolantCapacity=15,000 | ||
|coolantRefresh= | |coolantRefresh= | ||
|heatGeneration= | |heatGeneration= | ||
|heatDissipation= | |heatDissipation=150 per second | ||
|propellantIn= | |propellantIn= | ||
|propellantOut= | |propellantOut= | ||
| Line 46: | Line 45: | ||
|modInterfaces=1 | |modInterfaces=1 | ||
|deviceInterfaces= | |deviceInterfaces= | ||
|enhancement | |enhancement= | ||
}} | }} | ||
|{{SB Infobox Device Construction | |{{SB Infobox Device Construction | ||
|headerOverride= | |headerOverride= | ||
|aegisium= | |aegisium=10% | ||
|ajatite= | |ajatite= | ||
|arkanium= | |arkanium= | ||
|bastium= | |bastium=60% | ||
|charodium= | |charodium= | ||
|corazium= | |corazium= | ||
| Line 68: | Line 67: | ||
|oninum= | |oninum= | ||
|surtrite= | |surtrite= | ||
|tengium= | |tengium=20% | ||
|ukonium= | |ukonium= | ||
|valkite= | |valkite= | ||
|vokarium= | |vokarium=10% | ||
|xhalium= | |xhalium= | ||
}} | }} | ||
}}<section begin=summary/>The cooling rack | }}<section begin=summary/>The cooling rack plays an integral part in a [[Generator_(Assembly)|generator]], as it is one of the only devices that can provide the generator with the cooling capacity that they require to run. Unlike [[Radiator|radiators]], however, cooling racks need to be periodically replenished with refreshed [[Small_cooling_cell|small cooling cells]].<section end=summary/> | ||
== Basic Usage == | == Basic Usage == | ||
| Line 80: | Line 79: | ||
* The cooling board can hold up to three cooling cells. | * The cooling board can hold up to three cooling cells. | ||
* Receives '''Coolant''' from the cooling cells and processes it to reduce '''Heat'''. | * Receives '''Coolant''' from the cooling cells and processes it to reduce '''Heat'''. | ||
* The cooling board can be placed anywhere on a generator, and will provide coolant to each generator of the complex it is directly connected to. Generator complexes connected via pipe will not share coolant. | * The cooling board can be placed anywhere on a generator, and will provide coolant to each generator of the complex it is directly connected to. Generator complexes connected via pipe will not share coolant. | ||
* | * Only the calculated amount of '''Heat''' that the system produces is relevant. The cooling power of the cooling board must match the '''Heat''' amount produced, or preferably exceed it. | ||
* There is only one connector on the cooling board. | * There is only one connector on the cooling board. | ||
<!-- * If an enhancement effect is used on the cooling board, the efficiency rate of reducing '''Heat''' from processing '''Coolant''' increases. --> | |||
== Device fields == | == Device fields == | ||
| Line 114: | Line 109: | ||
*[[Generator (Assembly)]] | *[[Generator (Assembly)]] | ||
*[[ | *[[Coolant Cell]] | ||
[[Category:Devices and machines]] | [[Category:Devices and machines]] | ||
Revision as of 18:51, 21 June 2021
Cooling rack
Type Power device
Function Provides coolant to generators
Availability Luxury Items
Size 96×96×48 cm
Mass 731.23 kg
Volume 73.49 kv
Corrosion resistance 440
Input / Output
Coolant output 6 per second
Coolant capacity 15,000
Heat dissipation 150 per second
Modular interfaces 1
Composition
The cooling rack plays an integral part in a generator, as it is one of the only devices that can provide the generator with the cooling capacity that they require to run. Unlike radiators, however, cooling racks need to be periodically replenished with refreshed small cooling cells.
Basic Usage
- The cooling board can hold up to three cooling cells.
- Receives Coolant from the cooling cells and processes it to reduce Heat.
- The cooling board can be placed anywhere on a generator, and will provide coolant to each generator of the complex it is directly connected to. Generator complexes connected via pipe will not share coolant.
- Only the calculated amount of Heat that the system produces is relevant. The cooling power of the cooling board must match the Heat amount produced, or preferably exceed it.
- There is only one connector on the cooling board.
Device fields
| YOLOL field | Description | Range |
|---|---|---|
| CoolerUnitRateLimit | Upper limit for conversion rate for this cooler | 0 - 100 |
| CoolerUnitRate | Current conversion rate for this cooler. Conversion is being performed at 1 conversion * this percentage per second. | 0 - 100 |
To learn more about how to use fields, consult these wiki pages:
