Difference between revisions of "Socket board"
Jump to navigation
Jump to search
(removed device fields and fixed values that have changed) |
m (Minor edit for clarity with the use of tier 3 generators.) |
||
(4 intermediate revisions by 4 users not shown) | |||
Line 14: | Line 14: | ||
|{{SB Infobox Device General Information | |{{SB Infobox Device General Information | ||
|type=Power device | |type=Power device | ||
|function= | |function=Connectors [[Generator_(Assembly)|generators]] to the network | ||
|size=96×96×48 cm | |size=96×96×48 cm | ||
Line 27: | Line 27: | ||
|{{SB Infobox Device IO | |{{SB Infobox Device IO | ||
|electricIn= | |electricIn=10,000 | ||
|electricOut= | |electricOut=10,000 | ||
|energyCapacity= | |energyCapacity= | ||
|coolantIn= | |coolantIn= | ||
Line 74: | Line 74: | ||
|xhalium= | |xhalium= | ||
}} | }} | ||
}}<section begin=summary/>The socket board provides an access panel to connect [[Generator_(Assembly)|generators]] to the | }}<section begin=summary/>The socket board provides an access panel to connect [[Generator_(Assembly)|generators]] to the power network.<section end=summary/> | ||
== Basic Usage == | == Basic Usage == | ||
Line 83: | Line 81: | ||
* Connects cables. | * Connects cables. | ||
* Distributes '''Power''' to a [[Data networks|data network]]. | * Distributes '''Power''' to a [[Data networks|data network]]. | ||
* Can distribute a maximum of | * Can distribute a maximum of 10,000 '''Electricity''' per second. This means that one socket board per 9 tier 1/2 generators (3 tier 1/2 fuel chambers) is required. If tier 3 generators are used, one socket board is required per 8 generators (rather than 10 generators with lower tiers, since tier 3 generators produce 1250 eps each). | ||
* Doesn't get any benefits from enhancers. | * Doesn't get any benefits from enhancers. | ||
== Device fields == | |||
<section begin=deviceFields/> | |||
{|class="wikitable" | |||
! YOLOL field | |||
! Description | |||
! Range | |||
|- | |||
! '''SocketUnitRateLimit''' | |||
| Upper limit for conversion rate for this socket | |||
| 0 - 100 | |||
|- | |||
! '''SocketUnitRate''' | |||
| Current conversion rate for this socket. Output is being calculated at 1 eps * this percentage per second. | |||
| 0 - 100 (0-10000 eps) | |||
|- | |||
|}<section end=deviceFields/> | |||
To learn more about how to use fields, consult these wiki pages: | |||
* [[Universal tool|Universal Tool]] | |||
* [[Data networks|Data networks]] | |||
* [[YOLOL|YOLOL]] | |||
== Related Articles == | == Related Articles == |
Revision as of 04:34, 5 October 2021
Socket board
Type Power device
Function Connectors generators to the network
Size 96×96×48 cm
Mass 750.93 kg
Volume 75.47 kv
Corrosion resistance 390
Primary material Bastium
Input / Output
Electric input 10,000
Electric output 10,000
Sockets 4
Modular interfaces 1
Composition
The socket board provides an access panel to connect generators to the power network.
Basic Usage
- Transforms Local Power into Power.
- Connects cables.
- Distributes Power to a data network.
- Can distribute a maximum of 10,000 Electricity per second. This means that one socket board per 9 tier 1/2 generators (3 tier 1/2 fuel chambers) is required. If tier 3 generators are used, one socket board is required per 8 generators (rather than 10 generators with lower tiers, since tier 3 generators produce 1250 eps each).
- Doesn't get any benefits from enhancers.
Device fields
YOLOL field | Description | Range |
---|---|---|
SocketUnitRateLimit | Upper limit for conversion rate for this socket | 0 - 100 |
SocketUnitRate | Current conversion rate for this socket. Output is being calculated at 1 eps * this percentage per second. | 0 - 100 (0-10000 eps) |
To learn more about how to use fields, consult these wiki pages: