Sb forum speech.png DiscordLink.png FacebookLink.png RedditLink.png SteamLink.png TwitterLink.png YoutubeLink.png

Difference between revisions of "Cooling rack"

From Starbase wiki
Jump to navigation Jump to search
m
m
Line 74: Line 74:
  |xhalium=
  |xhalium=
}}
}}
}}<section begin=summary/>The cooling rack plays an integral part in a [[Generator_(Assembly)|generator]], as it is one of the only devices that can provide the generator with the cooling capacity that they require to run. Unlike [[Radiator|radiators]], however, cooling racks need to be periodically replenished with refreshed [[Small cooling cell|small cooling cells]].<section end=summary/>
}}<section begin=summary/>The cooling rack is a device used to provide a significant reduction in [[Heat mechanics|heat]] via [[Small cooling cell|coolant]]. Unlike a [[heatsink]] and [[radiator]] system, a coolant rack is not designed for long-term usage, as its coolant is quickly used up during operation and will require replenishing. Thus, it is best to design a [[Generator (Assembly)|generator]] which uses a combination of both systems.<section end=summary/>


== Basic Usage ==
== Basic Usage ==
Line 80: Line 80:
* The cooling board can hold up to three cooling cells.
* The cooling board can hold up to three cooling cells.
* Receives '''Coolant''' from the cooling cells and processes it to reduce '''Heat'''.
* Receives '''Coolant''' from the cooling cells and processes it to reduce '''Heat'''.
 
** Coolant cells will slowly replenish their supply of fresh coolant over time. However, a [[coolant recharge rack]] can be used to expedite this process.


* The cooling board can be placed anywhere on a generator, and will provide coolant to each generator of the complex it is directly connected to. Generator complexes connected via pipe will not share coolant.
* The cooling board can be placed anywhere on a generator, and will provide coolant to each generator of the complex it is directly connected to. Generator complexes connected via pipe will not share coolant.
* Cooling racks can provide 300 reduction in heat.
* A single coolant rack can provide up to 5,000 coolant per second (an entire coolant cell's capacity), and can disperse 5 units of heat with 1 unit of coolant. Thus, a coolant rack can disperse up to 25,000 heat per second.
** See [[Generator_(Assembly)#Heat_and_cooling|heat and cooling]] for more info.
** See [[Generator_(Assembly)#Heat_and_cooling|heat and cooling]] for more info.




* There is only one connector on the cooling board.
* There is only one connector on the cooling board.
* If an enhancement effect is used on the cooling board, the efficiency rate of reducing '''Heat''' from processing '''Coolant''' increases by increasing the maximum heat dissipation without increasing the coolant output. Only three enhancers will effect the coolant rack, and their maximum head dissipations are 300, 450, 525, and 562.5 for zero to three enhancers respectively.


== Device fields ==
== Device fields ==

Revision as of 16:54, 28 April 2022

Українська 日本語 简体中文
Starbase generator coolingboard.png
Cooling rack
Type Power device
Function Provides coolant to generators

Size 96×96×48 cm
Mass 731.23 kg
Volume 73.49 kv
Corrosion resistance 440
Primary material Bastium
Input / Output

Coolant output 5,000 per second
Coolant capacity 15,000

Modular interfaces 1

Composition

The cooling rack is a device used to provide a significant reduction in heat via coolant. Unlike a heatsink and radiator system, a coolant rack is not designed for long-term usage, as its coolant is quickly used up during operation and will require replenishing. Thus, it is best to design a generator which uses a combination of both systems.

Basic Usage

  • The cooling board can hold up to three cooling cells.
  • Receives Coolant from the cooling cells and processes it to reduce Heat.
    • Coolant cells will slowly replenish their supply of fresh coolant over time. However, a coolant recharge rack can be used to expedite this process.
  • The cooling board can be placed anywhere on a generator, and will provide coolant to each generator of the complex it is directly connected to. Generator complexes connected via pipe will not share coolant.
  • A single coolant rack can provide up to 5,000 coolant per second (an entire coolant cell's capacity), and can disperse 5 units of heat with 1 unit of coolant. Thus, a coolant rack can disperse up to 25,000 heat per second.


  • There is only one connector on the cooling board.

Device fields

YOLOL field Description Range
CoolerUnitRateLimit Upper limit for conversion rate for this cooler 0 - 100
CoolerUnitRate Current conversion rate for this cooler. Conversion is being performed at 1 conversion * this percentage per second. 0 - 100

To learn more about how to use fields, consult these wiki pages:

Related Articles

Cookies help us deliver our services. By using our services, you agree to our use of cookies.