Difference between revisions of "Cooling rack"
Jump to navigation
Jump to search
(Added enhancer data to sidebar and updated blurb about enhancers (last update was to correct coolant output, sorry for no summary!)) |
|||
Line 46: | Line 46: | ||
|modInterfaces=1 | |modInterfaces=1 | ||
|deviceInterfaces= | |deviceInterfaces= | ||
|enhancement= | |enhancement=<li>50% efficiency (1x)</li><li>75% efficiency (2x)</li><li>87.5% efficiency (3x)</li> | ||
}} | }} | ||
Line 88: | Line 88: | ||
* There is only one connector on the cooling board. | * There is only one connector on the cooling board. | ||
* If an enhancement effect is used on the cooling board, the efficiency rate of reducing '''Heat''' from processing '''Coolant''' increases. | * If an enhancement effect is used on the cooling board, the efficiency rate of reducing '''Heat''' from processing '''Coolant''' increases by increasing the maximum heat dissipation without increasing the coolant output. Only three enhancers will effect the coolant rack, and their maximum head dissipations are 300, 450, 525, and 562.5 for zero to three enhancers respectively. | ||
== Device fields == | == Device fields == |
Revision as of 09:05, 17 February 2022
Cooling rack
Type Power device
Function Provides coolant to generators
Size 96×96×48 cm
Mass 731.23 kg
Volume 73.49 kv
Corrosion resistance 440
Primary material Bastium
Input / Output
Coolant output 4 per second
Coolant capacity 15,000
Heat dissipation 300 per second
Modular interfaces 1
Enhancement effect 50% efficiency (1x) 75% efficiency (2x) 87.5% efficiency (3x)
Composition
The cooling rack plays an integral part in a generator, as it is one of the only devices that can provide the generator with the cooling capacity that they require to run. Unlike radiators, however, cooling racks need to be periodically replenished with refreshed small cooling cells.
Basic Usage
- The cooling board can hold up to three cooling cells.
- Receives Coolant from the cooling cells and processes it to reduce Heat.
- The cooling board can be placed anywhere on a generator, and will provide coolant to each generator of the complex it is directly connected to. Generator complexes connected via pipe will not share coolant.
- Cooling racks can provide 300 reduction in heat.
- See heat and cooling for more info.
- There is only one connector on the cooling board.
- If an enhancement effect is used on the cooling board, the efficiency rate of reducing Heat from processing Coolant increases by increasing the maximum heat dissipation without increasing the coolant output. Only three enhancers will effect the coolant rack, and their maximum head dissipations are 300, 450, 525, and 562.5 for zero to three enhancers respectively.
Device fields
YOLOL field | Description | Range |
---|---|---|
CoolerUnitRateLimit | Upper limit for conversion rate for this cooler | 0 - 100 |
CoolerUnitRate | Current conversion rate for this cooler. Conversion is being performed at 1 conversion * this percentage per second. | 0 - 100 |
To learn more about how to use fields, consult these wiki pages: