Ships will require enough batteries to act as a buffer for the generator spool up time.
 
The following scripts are made to be used with the ship "[[Laborer module|Laborer Module]]" rewarded during the tutorials. To make it compatible with other prebuilt or own-made ships, refer to the table below for the corresponding modifications in the [[Device fields|device fields]].
 
{| class="wikitable"
! Ship Part !! Default Field Name !! Laborer Module Field Name
|-
| Fuel Chamber || FuelChamberUnitRateLimit || Generator
|-
| First Battery || StoredBatteryPower || Battery_1
|-
| Second Battery || StoredBatteryPower || Battery_2
|}
 
Also, ships will require enough batteries to act as buffers during the generator spool up time. ''Note: When in use, all batteries discharge at the same rate. The more batteries you have, the slower the discharge is.''


==="Standard" Generator Script===
==="Standard" Generator Script===
:FuelChamberUnitRateLimit=100-:StoredBatteryPower/100 goto 1


Makes the fuel chambers' rate limit follow the battery charge inversely.
Makes the fuel rate limit of the fuel chamber inversely proportional to the charge level of the batteries.
''<br/>Note: The [[Laborer Module]] ship rewarded during the tutorial has these fields renamed by default to: <code>Generator</code> and <code>Battery_1</code>''


==="Alternative" Generator Script===
:Generator=100-:Battery_1/100 goto1


An alternative script that will keep the batteries fuller.
Alternatively, this script will keep the batteries fuller by setting the fuel rate limit to its maximum when batteries are below 90% of charge.


  :FuelChamberUnitRateLimit=1000-:StoredBatteryPower/10 goto 1
  :Generator=1000-:Battery_1/10 goto1


===Settable on/off Generator flag===
===Flagged Generator Script===
:Generator=22*(:Battery_1>5000)*(:Battery_1<9999)+0.001 goto1


This script set the fuel rate limit to 22% (just enough to supply 2 box thrusters) if the charge level of the batteries is between 5000 (start-charging level) and 9999 (stop-charging level). 0.001% is enough fuel rate to let the generator "sleep" when the ship is not moving.


5000 and 9999 are the start-charging and stop-charging levels. 22% is just enough charge to run the stock two box thrusters.
:Generator=22*(:Battery_1>5000)*(:Battery_1<9999)+0.001 goto1


===Tweakable Generator Script===
===Advanced Generator Script===


This script is tweakable to your ship configuration and also by an on/off button and/or override lever. Field renamings are those of the default Laborer, except for the :FCRL field. This field needs a new name so that the script can control the fuel rate, instead of the Generator button.
This script is tweakable to your ship configuration. Field names are those of the Laborer Module, except for the '''"Generator"''' button which should be renamed '''"PWR"''' so the script can control the fuel rate while the button still being functional. Optionally you can add an override lever with '''"LeverState"''' renamed '''"PWR"''' as well.


  MaxBattery=20000          // total capacity
  MaxBattery=20000          // total capacity
Line 56: Line 67:
  f=MaxBattery l=LowBattery e=MinBattery // no need to change these
  f=MaxBattery l=LowBattery e=MinBattery // no need to change these
  r=(h-c)/(f-e) z=h-r*l a=r*(f-l)      // reboot: remove "goto9" briefly
  r=(h-c)/(f-e) z=h-r*l a=r*(f-l)      // reboot: remove "goto9" briefly
  y=:Generator-z-r*(:Battery_1+:Battery_2)+c*(y>c)+a*(y>0) :FCRL=y goto9
  y=:PWR-z-r*(:Battery_1+:Battery_2)+c*(y>c)+a*(y>0) :Generator=y goto9


It is assumed that specific YOLOL fields are renamed:
It is assumed that the following device fields are set as explained (''Note: The "PWR" button is already set up in the Laborer Module''):
{| class="wikitable"
|+ Renamed fields
|-
! Ship Part !! Old YOLOL field name (Laborer in parenthesis) !! New YOLOL field name
|-
| On/Off Button || ButtonState (Generator) || Generator
|-
| First Battery || StoredBatteryPower (Battery_1) || Battery_1
|-
| Second Battery || StoredBatteryPower (Battery_2) || Battery_2
|-
| Fuel Chamber || FuelChamberUnitRateLimit (Generator) || FCRL
|-
| Override Lever (optional) || LeverState || Generator
|}


It is assumed that specific YOLOL fields have the specific values below. The on/off button is already set up in the basic laborer.
{| class="wikitable"
{| class="wikitable"
|+ Fixed field values
! Ship Part !! Field Name !! Set Field value
|-
! Ship Part !! YOLOL field name !! Fixed field value (Laborer default in parenthesis)
|-
|-
| On/Off Button || ButtonOnStateValue|| 100 (100)
| "PWR" Button || ButtonOnStateValue|| 100
|-
|-
| On/Off Button || ButtonOffStateValue|| 0 (0)
| "PWR" Button || ButtonOffStateValue|| 0  
|-
|-
| On/Off Button || ButtonStyle || 1 (1)
| "PWR" Button || ButtonStyle || 1
|-
|-
| Override Lever (optional) || LeverMinOutput || 0  
| "PWR" Lever (optional) || LeverMinOutput || 0  
|-
|-
| Override Lever (optional) || LeverMaxOutput || 200  
| "PWR" Lever (optional) || LeverMaxOutput || 200  
|-
|-
| Override Lever (optional) || LeverCenteringSpeed || 0
| "PWR" Lever (optional) || LeverCenteringSpeed || 0
|}
|}



Revision as of 20:21, 15 February 2022

A collection of small common scripts meant to be easily copied and understood for the YOLOL beginner.

This page is a "Work In Progress". Don't hesitate to contribute! Just make sure to respect the following rules:

  • Avoid complex codes. As said, These must be easily understood by beginners. If you can't simplify your scripts, please add some comments to explain the most technical parts.
  • Avoid as possible to modify the device fields. If necessary, it must be specified which variable has to be renamed (left column) and/or set to a given value (right column).

Flight Control Unit

Single Forward/Backward Lever

Requires a center lever bound to "FcuForward". Note: You can easily modify the default regular lever from most prebuilt ships and cockpit modules to be used as a center Lever. Just change the "LeverMinOutput" value from 0 to -100.

:FcuBackward=-:FcuForward goto1

Speed Limiter

Requires to modify the lever bound to "FcuForward" which shall be renamed "Fwd" and another regular lever with "LeverState" renamed "Limiter". This script allow you to set a maximum forward speed to your ship, which is useful when you need more accurate movements (e.g. while mining or docking).

:FcuForward=:Fwd/100*:Limiter goto1

Note: If you already modified your "FcuFoward" lever to be used as a "Single Forward/Backward Lever" (see above), you can use the "Backward" lever made useless as the "Limiter" lever. Just make sure you have "FcuForward" renamed "FwdBwd" instead so you can modify forward and backward thrust individually. This way your YOLOL scripts should be written as follows:

:FcuForward=:FwdBwd/100*:Limiter goto1
:FcuBackward=-:FwdBwd goto1

Turtle Mode

Similar to the previous script but with a button instead of a lever. "ButtonState" should be renamed "Turtle" and "ButtonStyle" set to "1". In addition set the "ButtonOffStateValue" to "100" and the "ButtonOnStateValue" to the desired speed reduction. For example having "30" means 30% of maximum speed when the button is active.

:FcuForward=:Fwd/100*:Turtle goto1

Fuel Chamber

The following scripts are made to be used with the ship "Laborer Module" rewarded during the tutorials. To make it compatible with other prebuilt or own-made ships, refer to the table below for the corresponding modifications in the device fields.

Ship Part Default Field Name Laborer Module Field Name
Fuel Chamber FuelChamberUnitRateLimit Generator
First Battery StoredBatteryPower Battery_1
Second Battery StoredBatteryPower Battery_2

Also, ships will require enough batteries to act as buffers during the generator spool up time. Note: When in use, all batteries discharge at the same rate. The more batteries you have, the slower the discharge is.

"Standard" Generator Script

Makes the fuel rate limit of the fuel chamber inversely proportional to the charge level of the batteries.

:Generator=100-:Battery_1/100 goto1

Alternatively, this script will keep the batteries fuller by setting the fuel rate limit to its maximum when batteries are below 90% of charge.

:Generator=1000-:Battery_1/10 goto1

Flagged Generator Script

This script set the fuel rate limit to 22% (just enough to supply 2 box thrusters) if the charge level of the batteries is between 5000 (start-charging level) and 9999 (stop-charging level). 0.001% is enough fuel rate to let the generator "sleep" when the ship is not moving.

:Generator=22*(:Battery_1>5000)*(:Battery_1<9999)+0.001 goto1

Advanced Generator Script

This script is tweakable to your ship configuration. Field names are those of the Laborer Module, except for the "Generator" button which should be renamed "PWR" so the script can control the fuel rate while the button still being functional. Optionally you can add an override lever with "LeverState" renamed "PWR" as well.

MaxBattery=20000           // total capacity
LowBattery=0.99*MaxBattery // start charging below 99%
MinBattery=0.20*MaxBattery // max charge rate below 20%
MaxGenerator=100           // max fuel rate
MinGenerator=2             // min fuel rate (near 100% charge)
h=MaxGenerator c=MinGenerator          // auxiliary variables,
f=MaxBattery l=LowBattery e=MinBattery // no need to change these
r=(h-c)/(f-e) z=h-r*l a=r*(f-l)      // reboot: remove "goto9" briefly
y=:PWR-z-r*(:Battery_1+:Battery_2)+c*(y>c)+a*(y>0) :Generator=y goto9

It is assumed that the following device fields are set as explained (Note: The "PWR" button is already set up in the Laborer Module):

Ship Part Field Name Set Field value
"PWR" Button ButtonOnStateValue 100
"PWR" Button ButtonOffStateValue 0
"PWR" Button ButtonStyle 1
"PWR" Lever (optional) LeverMinOutput 0
"PWR" Lever (optional) LeverMaxOutput 200
"PWR" Lever (optional) LeverCenteringSpeed 0

Material Point Scanner

Material Point Scanner Script

Requires 2 displays for "Material" and "Volume", 2 buttons to toggle "Active" and "Scan" and a third one with "ButtonState" renamed "Next" and "ButtonStyle" set to "1".

:Index=(:Index+:Next)*(:Index<:ScanResults) :Next=0
:Material=:Material :Volume=:Volume goto1

Automatic Material Point Scanner Script

This is a modified version of the above script so it can be used when the scanner is "Active" without the need of any additional buttons. Note: launching a new scan reinitialize the index to "0".

:Scan=1
//Pause
:Index=Next
Next=(Next+1)*(Next<:ScanResults)
:Material=:Material :Volume=:Volume goto1

Mining Laser

Pulsed Mining Laser

Requires a button with "ButtonState" renamed "Mining" and "ButtonStyle" set to "1". Reduces power consumption by continuously switching mining laser "on" and "off" while the button is active.

:MiningLaserOn=(1-:MiningLaserOn)*:Mining goto1

Configurable Pulsed Mining Laser

Similar to the previous script but with configurable timers for the "On" and "Off" phases of the laser. Note: Each phase is calculated in number of YOLOL "tick" (0.2sec). So in the example, the "On" phase last 2*0.2=0.4sec and the "Off" phase 3*0.2=0.6 sec, which makes the power comsumption just a bit lower than the power production of a generator module (= one fuel chamber and three generator units, all in tier 1).

On=2 Off=3 :MiningLaserOn=(T<On)*:Mining T++ T*=T<(On+Off) goto1

Navigation Receiver

Received Signal Display

Requires a text panel with "PanelValue" renamed "Nav".

if :SignalStrength>0 then goto2 else :Nav="No Signal" goto1 end
:Nav=:Message+"\n"+(1000000-:SignalStrength)/1000+"km" goto1

Ore Collector

Mining Laser/ Ore Collector Switching

Requires a button with "ButtonState" renamed "Collecting" and "ButtonStyle" set to "1". Reduces power consumption by switching ore collector "On" only if the button is active And the mining laser is "Off". Note: this script works best alongside the "Pulsed Mining Laser" scripts.

:ToggleOn=(1-:MiningLaserOn)*:Collecting goto1

Ship Transponder

Outside Safezone Warning

Requires an active transponder and either a warning button or a safety lid button. The button blink whenever you're outside of the safe zone. Note: the button needs to be On in order to blink.

:ButtonEnableBlink=1-:InsideSafeZone goto1

Stations Building Availability

Same as the previous one, but the button blink wherever you're allowed to build a station.

:ButtonEnableBlink=:StationsAllowed goto1