Difference between revisions of "Cooling rack"
Jump to navigation
Jump to search
m |
|||
Line 2: | Line 2: | ||
|zh-cn=冷却室槽 | |zh-cn=冷却室槽 | ||
|ua=Плата охолодження | |ua=Плата охолодження | ||
}} | }}{{SB Infobox Begin | ||
|{{SB Infobox Header | |||
|image=[[Image:Starbase_generator_coolingboard.png]] | |||
|factionLogo= | |||
|caption= | |||
|name= | |||
|border=none | |||
}} | |||
|{{SB Infobox Device General Information | |||
|type=Power device | |||
|function=Provides [[Coolant|coolant]] to [[Generator_(Assembly)|generators]] | |||
|availability=[[Luxury Items]] | |||
|size=96×96×48 cm | |||
|mass=731.23 | |||
|volume=73.49 | |||
|corrosionResistance=440 | |||
|suppressUnitsKg | |||
|suppressUnitsKv | |||
|subComponents= | |||
}} | |||
|{{SB Infobox Device IO | |||
|electricIn= | |||
|electricOut= | |||
|energyCapacity= | |||
|coolantIn= | |||
|coolantOut=6 per second | |||
|coolantCapacity=15,000 | |||
|coolantRefresh= | |||
|heatGeneration= | |||
|heatDissipation=150 per second | |||
|propellantIn= | |||
|propellantOut= | |||
|propellantCapacity | |||
|fuelIn= | |||
|fuelOut= | |||
|fuelCapacity | |||
|sockets= | |||
|YOLOLchips= | |||
|modInterfaces= | |||
|deviceInterfaces=1 | |||
|enhancement= | |||
}} | |||
|{{SB Infobox Device Construction | |||
|headerOverride= | |||
|aegisium=10% | |||
|ajatite= | |||
|arkanium= | |||
|bastium=60% | |||
|charodium= | |||
|corazium= | |||
|exorium= | |||
|haderite= | |||
|ice= | |||
|ilmatrium= | |||
|karnite= | |||
|kutonium= | |||
|lukium= | |||
|merkerium= | |||
|nhurgite= | |||
|oninum= | |||
|surtrite= | |||
|tengium=20% | |||
|ukonium= | |||
|valkite= | |||
|vokarium=10% | |||
|xhalium= | |||
}} | |||
}}<section begin=summary/>The cooling rack plays an integral part in a [[Generator_(Assembly)|generator]], as it is one of the only devices that can provide the generator with the cooling capacity that they require to run. Unlike [[Radiators|radiators]], however, cooling racks need to be periodically replenished with refreshed [[Coolant cells|coolant cells]].<section end=summary/> | |||
== Basic Usage == | |||
* The cooling board can hold up to three cooling cells. | * The cooling board can hold up to three cooling cells. | ||
* Receives '''Coolant''' from the cooling cells and processes it to reduce '''Heat'''. | * Receives '''Coolant''' from the cooling cells and processes it to reduce '''Heat'''. | ||
Line 16: | Line 82: | ||
* There is only one connector on the cooling board. | * There is only one connector on the cooling board. | ||
<!-- * If an enhancement effect is used on the cooling board, the efficiency rate of reducing '''Heat''' from processing '''Coolant''' increases. --> | <!-- * If an enhancement effect is used on the cooling board, the efficiency rate of reducing '''Heat''' from processing '''Coolant''' increases. --> | ||
== Device fields == | == Device fields == | ||
{|class="wikitable" | {|class="wikitable" | ||
! YOLOL field | ! YOLOL field | ||
Line 50: | Line 99: | ||
|- | |- | ||
|} | |} | ||
To learn more about how to use fields, consult these wiki pages: | |||
* [[Universal tool|Universal Tool]] | |||
* [[Data networks|Data networks]] | |||
* [[YOLOL|YOLOL]] | |||
| | |||
== Related Articles == | |||
| | |||
| | *[[Generator_(Assembly)]] | ||
*[[Coolant Cell]] | |||
[[Category:Devices and machines]] | [[Category:Devices and machines]] |
Revision as of 11:53, 28 May 2021
Cooling rack
Type Power device
Function Provides coolant to generators
Availability Luxury Items
Size 96×96×48 cm
Mass 731.23 kg
Volume 73.49 kv
Corrosion resistance 440
Input / Output
Coolant output 6 per second
Coolant capacity 15,000
Heat dissipation 150 per second
Device interfaces 1
Composition
The cooling rack plays an integral part in a generator, as it is one of the only devices that can provide the generator with the cooling capacity that they require to run. Unlike radiators, however, cooling racks need to be periodically replenished with refreshed coolant cells.
Basic Usage
- The cooling board can hold up to three cooling cells.
- Receives Coolant from the cooling cells and processes it to reduce Heat.
- The cooling board can be placed anywhere on a generator, and will provide coolant to each generator of the complex it is directly connected to. Generator complexes connected via pipe will not share coolant.
- Only the calculated amount of Heat that the system produces is relevant. The cooling power of the cooling board must match the Heat amount produced, or preferably exceed it.
- There is only one connector on the cooling board.
Device fields
YOLOL field | Description | Range |
---|---|---|
CoolerUnitRateLimit | Upper limit for conversion rate for this cooler | 0 - 100 |
CoolerUnitRate | Current conversion rate for this cooler. Conversion is being performed at 1 conversion * this percentage per second. | 0 - 100 |
To learn more about how to use fields, consult these wiki pages: