Difference between revisions of "Socket board"
Jump to navigation
Jump to search
m (Text replacement - "|availability=Luxury Items" to "") |
m (Minor edit for clarity with the use of tier 3 generators.) |
||
Line 81: | Line 81: | ||
* Connects cables. | * Connects cables. | ||
* Distributes '''Power''' to a [[Data networks|data network]]. | * Distributes '''Power''' to a [[Data networks|data network]]. | ||
* Can distribute a maximum of 10,000 ''' | * Can distribute a maximum of 10,000 '''Electricity''' per second. This means that one socket board per 9 tier 1/2 generators (3 tier 1/2 fuel chambers) is required. If tier 3 generators are used, one socket board is required per 8 generators (rather than 10 generators with lower tiers, since tier 3 generators produce 1250 eps each). | ||
* Doesn't get any benefits from enhancers. | * Doesn't get any benefits from enhancers. | ||
Line 93: | Line 93: | ||
! '''SocketUnitRateLimit''' | ! '''SocketUnitRateLimit''' | ||
| Upper limit for conversion rate for this socket | | Upper limit for conversion rate for this socket | ||
| 0 - 100 | | 0 - 100 | ||
|- | |- | ||
! '''SocketUnitRate''' | ! '''SocketUnitRate''' | ||
| Current conversion rate for this socket. | | Current conversion rate for this socket. Output is being calculated at 1 eps * this percentage per second. | ||
| 0 - 100 | | 0 - 100 (0-10000 eps) | ||
|- | |- | ||
|}<section end=deviceFields/> | |}<section end=deviceFields/> |
Revision as of 03:34, 5 October 2021
Socket board
Type Power device
Function Connectors generators to the network
Size 96×96×48 cm
Mass 750.93 kg
Volume 75.47 kv
Corrosion resistance 390
Primary material Bastium
Input / Output
Electric input 10,000
Electric output 10,000
Sockets 4
Modular interfaces 1
Composition
The socket board provides an access panel to connect generators to the power network.
Basic Usage
- Transforms Local Power into Power.
- Connects cables.
- Distributes Power to a data network.
- Can distribute a maximum of 10,000 Electricity per second. This means that one socket board per 9 tier 1/2 generators (3 tier 1/2 fuel chambers) is required. If tier 3 generators are used, one socket board is required per 8 generators (rather than 10 generators with lower tiers, since tier 3 generators produce 1250 eps each).
- Doesn't get any benefits from enhancers.
Device fields
YOLOL field | Description | Range |
---|---|---|
SocketUnitRateLimit | Upper limit for conversion rate for this socket | 0 - 100 |
SocketUnitRate | Current conversion rate for this socket. Output is being calculated at 1 eps * this percentage per second. | 0 - 100 (0-10000 eps) |
To learn more about how to use fields, consult these wiki pages: