Difference between revisions of "Small cooling cell"
Jump to navigation
Jump to search
(4 intermediate revisions by the same user not shown) | |||
Line 97: | Line 97: | ||
}}<section begin=summary/>Cooling cells are devices used in [[Cooling rack|cooling racks]] to supply a [[Generator (Assembly)|Generator]] with fresh coolant, which it regenerates passively. The passive regeneration can be improved in a [[Coolant recharge rack|Recharge rack]]. | }}<section begin=summary/>Cooling cells are devices used in [[Cooling rack|cooling racks]] to supply a [[Generator (Assembly)|Generator]] with fresh coolant, which it regenerates passively. The passive regeneration can be improved in a [[Coolant recharge rack|Recharge rack]]. | ||
<section end=summary/> | <section end=summary/> | ||
== Basic Use == | == Basic Use == | ||
* Put in a [[Cooling rack]] it allows the cooling rack to cool the attached [[Generator_(Assembly)|Generator Assembly]]. | * Put in a [[Cooling rack]] it allows the cooling rack to cool the attached [[Generator_(Assembly)|Generator Assembly]]. | ||
* Put in a [[Coolant recharge rack]] it regenerates coolant faster at the cost of electricity, but does not contribute to heat removal. | * Put in a [[Coolant recharge rack]] it regenerates coolant faster at the cost of electricity, but does not contribute to heat removal. | ||
* '''Note''' as the coolant cell regenerates coolant by itself you can craft an empty cell, circumventing the [[Nhurgite]] cost. | * '''Note''' as the coolant cell regenerates coolant by itself you can craft an empty cell, circumventing the [[Nhurgite]] cost. | ||
<section end= | |||
== Device fields == | |||
<section begin=deviceFields/> | |||
{|class="wikitable" | |||
! YOLOL field | |||
! Description | |||
! Range | |||
|- | |||
! '''CoolantPriority''' | |||
| Cells with a higher priority get used up first and refilled last | |||
| integer | |||
|- | |||
! '''StoredCoolant''' | |||
| Current amount of coolant in this cooling cell | |||
| 0 - MaxCoolant | |||
|- | |||
! '''MaxCoolant''' | |||
| Maximum amount of coolant that can be stored in the cooling cell | |||
| 10000 | |||
|- | |||
|}<section end=deviceFields/> | |||
== Related Pages == | == Related Pages == |
Latest revision as of 00:03, 19 March 2023
Small cooling cell
Type Cooling device
Function Stores coolant
Size 48×24×48 cm
Mass 251.7 kg
Volume 29.27 kv
Corrosion resistance 300
Primary material Bastium
Input / Output
Coolant capacity 10,000
Coolant recycle rate 1/s
15/s in a Recharge rack
15/s in a Recharge rack
Heat dissipation Up to 25,000 per second
Composition
Composition (Refill)
Cooling cells are devices used in cooling racks to supply a Generator with fresh coolant, which it regenerates passively. The passive regeneration can be improved in a Recharge rack.
Basic Use
- Put in a Cooling rack it allows the cooling rack to cool the attached Generator Assembly.
- Put in a Coolant recharge rack it regenerates coolant faster at the cost of electricity, but does not contribute to heat removal.
- Note as the coolant cell regenerates coolant by itself you can craft an empty cell, circumventing the Nhurgite cost.
Device fields
YOLOL field | Description | Range |
---|---|---|
CoolantPriority | Cells with a higher priority get used up first and refilled last | integer |
StoredCoolant | Current amount of coolant in this cooling cell | 0 - MaxCoolant |
MaxCoolant | Maximum amount of coolant that can be stored in the cooling cell | 10000 |