Difference between revisions of "Rail sensor strip"
Jump to navigation
Jump to search
m |
m |
||
Line 7: | Line 7: | ||
}}{{SB Infobox Begin | }}{{SB Infobox Begin | ||
|{{SB Infobox Header | |{{SB Infobox Header | ||
|image=[[Image:Starbase | |image=[[Image:Starbase sensor strip.png]] | ||
|factionLogo= | |factionLogo= | ||
|caption= | |caption= | ||
Line 13: | Line 13: | ||
|border=none | |border=none | ||
}} | }} | ||
<!-- | |||
|{{SB Infobox Device General Information | |{{SB Infobox Device General Information | ||
|type= | |type= | ||
|function= | |function= | ||
|availability= | |availability= | ||
|size= | |size= | ||
|mass= | |mass= | ||
|volume= | |volume= | ||
Line 37: | Line 37: | ||
|heatDissipation | |heatDissipation | ||
|propellantIn= | |propellantIn= | ||
|propellantOut= | |propellantOut= | ||
|propellantCapacity | |propellantCapacity | ||
|fuelIn= | |fuelIn= | ||
Line 48: | Line 48: | ||
}} | }} | ||
|{{SB Infobox Device Construction | |{{SB Infobox Device Construction | ||
|headerOverride= | |headerOverride= | ||
Line 82: | Line 73: | ||
|xhalium= | |xhalium= | ||
}} | }} | ||
}}<section begin=summary/> | --> | ||
}}<section begin=summary/>The sensor strip provides accurate positioning data for [[Rail mover|rail movers]] that pass it on the rail the sensor strip is connected to.<br> | |||
This enables the tracking of the rail mover's precise location at any point.<section end=summary/> | |||
The sensor strip provides accurate positioning data for [[Rail mover|rail movers]] that pass it on the rail the sensor strip is connected to.<br> | |||
This enables the tracking of the rail mover's precise location at any point. | |||
== Basic information == | == Basic information == |
Revision as of 09:09, 27 May 2021
The sensor strip provides accurate positioning data for rail movers that pass it on the rail the sensor strip is connected to.
This enables the tracking of the rail mover's precise location at any point.
Basic information
- When bolted to a rail, the sensor strip detects movers passing over it
- The sensor strip adjusts the device field variable to report the distance between the detected mover's center and one end of the strip
- In case the strip detects multiple movers, it reports the distance of the mover closest to the end
- A delta-variable can be changed to enable multiple strips working in a sequence to provide accurate positioning data along a large rail section
- The user can also set a variable to make the strip only detect movers with a specific RailMoverTriggerValue
- The sensor strip adjusts the device field variable to report the distance between the detected mover's center and one end of the strip
Device fields
To learn more about how to use fields, consult these wiki pages:
YOLOL field | description | range |
---|---|---|
RailSensorOutput | The output field the sensor strip writes to. Decimal metres. | Without delta: [0,0.960], with delta: any numeric |
RailSensorDelta | Value added to the detected range before writing the result to RailSensorOutput | Numeric, any |
RailSensorMoverFilter | If non-zero, the strip only detects movers with RailMoverTriggerValue equal to this. |