Difference between revisions of "Cooling rack"
Jump to navigation
Jump to search
m (→Summary) |
(reverting mistaken edit) |
||
Line 11: | Line 11: | ||
* The cooling board can hold up to three cooling cells. | * The cooling board can hold up to three cooling cells. | ||
* Receives '''Coolant''' from the cooling cells and processes it to reduce '''Heat'''. | * Receives '''Coolant''' from the cooling cells and processes it to reduce '''Heat'''. | ||
* The cooling board can be placed anywhere | * The cooling board can be placed anywhere. The cooling pipes running through the whole system will handle the cooling of all the fuel chambers and generator units. | ||
* It can also be placed on a separate coolant socket board and connected to the generator network through pipes. | |||
* Only the calculated amount of '''Heat''' that the system produces is relevant. The cooling power of the cooling board must match the '''Heat''' amount produced, or preferably exceed it. | * Only the calculated amount of '''Heat''' that the system produces is relevant. The cooling power of the cooling board must match the '''Heat''' amount produced, or preferably exceed it. | ||
* There is only one connector on the cooling board. | * There is only one connector on the cooling board. |
Revision as of 09:19, 4 December 2020
Summary
- The cooling board can hold up to three cooling cells.
- Receives Coolant from the cooling cells and processes it to reduce Heat.
- The cooling board can be placed anywhere. The cooling pipes running through the whole system will handle the cooling of all the fuel chambers and generator units.
- It can also be placed on a separate coolant socket board and connected to the generator network through pipes.
- Only the calculated amount of Heat that the system produces is relevant. The cooling power of the cooling board must match the Heat amount produced, or preferably exceed it.
- There is only one connector on the cooling board.
Cooling cells
- Stores the Coolant.
- Placed inside a cooling board.
- Distributes Coolant to the cooling board.
- Cooling Cells can be recharged in a Coolant refill rack.
Device fields
To learn more about how to use fields, consult these wiki pages:
Cooling Rack
YOLOL field | Description | Range |
---|---|---|
CoolerUnitRateLimit | Upper limit for conversion rate for this cooler | 0 - 100 |
CoolerUnitRate | Current conversion rate for this cooler. Conversion is being performed at 1 conversion * this percentage per second. | 0 - 100 |
Cooling Cell
YOLOL field | Description | Range |
---|---|---|
CoolantPriority | Lower values are used first | |
UsedCoolantPriority | Lower values are used first | |
StoredCoolant | The amount of coolant currently available in this cell | 0 - 5000 |
MaxCoolant | Maximum amount of coolant that can be stored in a coolant cell | 5000 |