== Summary == | == Summary == | ||
Line 28: | Line 37: | ||
=== Device tool === | === Device tool === | ||
The universal tool includes device interaction functionality by default that is used to monitor and configure | The universal tool includes device interaction functionality by default that is used to monitor and configure [[Device fields]], programmable chips, and device controls. | ||
* With the tool open it can be used to connect to devices in the world. | * With the tool open it can be used to connect to devices in the world. | ||
Line 101: | Line 110: | ||
== How to buy == | == How to buy == | ||
The universal is standard equipment of every robot and it is included in every new activation of an endoskeleton.<br> | The universal tool is standard equipment of every robot and it is included in every new activation of an endoskeleton.<br> | ||
[[Category: | [[Category:Hand tools|Universal tool]] |
Latest revision as of 06:16, 25 July 2021
Summary
The universal tool is a foldable forearm-mounted screen used to interact with both mechanical devices and some tools.
Basic information
The display of the universal tool consists of three basic parts: the main display and two smaller side-panels, which are folded out when needed.
The left panel is used as the main menu of the universal tool and contains a list of all main display and right panel modes available.
- Collapsible from a button
- Contains a list of modes
- Each tool with an additional universal tool interface has its own mode
- New modes appear in the list as they are unlocked
- Collapsed by default when screen is folded open
The main display and right panel are mode-specific
- Right panel is usually collapsible
- A header bar contains tabs for any sub-modes required
Tool views
There are multiple different views inside the universal tool.
These include for example:
Device tool
The universal tool includes device interaction functionality by default that is used to monitor and configure Device fields, programmable chips, and device controls.
- With the tool open it can be used to connect to devices in the world.
- Three tabs: Data, Resource, Binds
- Data tab is used to interact with device fields and for monitoring data network traffic.
- Resource tab is used to monitor device resource connections and processes.
- Binds tab is used to configure device controls for pilot and gunner chairs and such.
- Accessible when sitting in pilot chairs.
- The right panel is collapsible and identical between the other main tabs
- Can be used to view a summary of the data and resource tabs
- Contains option for device renaming
Data tab
Fields list
- Displays all connected device fields
- Device's own fields are sorted on the top
- Names and values can be edited by double-clicking on them
- External fields are sorted below the internal ones, in alphabetical order
- Names and values cannot be edited
- All fields can be selected and multiple fields can be selected simultaneously as well.
- A filter search field is included for finding specific fields in a large network more easily
- Device's own fields are sorted on the top
Network log
- Contains a running log of all device field broadcasts in the connected network
- A button can also be pressed to limit the view to any fields selected in the fields-list
- Fits a maximum of 100 entries
- Flood filter options can be used to assist viewing networks with a lot of traffic
- Maximum value differential only shows new entries for a field if the value differs from the previously reported one significantly
- Maximum time differential only shows new entries for a field if enough time has passed since the previous report
Resource tab
Conversions list
- Shows basic information about all resource conversions running in the selected device
- Conversions are listed based on the primary objective of the conversion
- Status column shows the current operation rate (relative to the maximum capability), or an error-message if the conversion is halted due to an error
- Conversions can be selected to limit the status display to resources related to the selected conversion, helping to analyse issues in detail
Status panel
- Shows resource status for all resources handled in the current device
- Simple view is open by default and can be used to quickly analyse connection problems
- Lists all resources required as input or produced as output for any conversion
- Shows an error message for any problems
- Advanced view can be selected to show resource flow in more detail
- Shows all resources involved in conversions within the device, or stored in the device
- Information includes the current rate and storage capacity of the resource, both internally and in total for the connected resource network
- Any errors are also shown based on the resource
Binds tab
Bind options
- Options for the selected device bind and bound key/axis
- Shows information relevant to the device and bind types
Bind list
- Lists all bindable devices
- Devices with default binds are sorted on top of other devices
- Shows custom and default binds for all device interactions
- Highlights default bind when it is active
- Highlights custom bind when it is active
- Header has a dropdown menu for selecting from different bindsets
- Selecting a device from the list acts like selecting a device from the actual world
Right side panel
The right side panel shows a summary of the simple resource view status, the device's health and connection strength to universal tool, as well as editable fields for the device's name and internal fields.
- Accessible from all tabs by pressing a button to fold the side panel out or in
- Can be used to quickly edit device fields or view resource connection status
How to buy